Overvoltage This is caused by a high intermediate circuit DC voltage. This can arise from high inertia loads decelerating too quickly, the motor turns into a generator and increases the inverter’s DC voltage. There are other causes of DC overvoltage, however. POSSIBLE FIXES: 1. Turn the overvoltage controller is. .
This is detected by an imbalance of the currents supplying the motor implying a leakage current to earth is present. This is usually caused by poor insulation resistance to earth. POSSIBLE FIXES: 1. Check insulation resistance of the motor and cabling. 2.. .
We hope you found the information in this article useful if you have a fault not listed and you need technical assistance contact our engineering team. .
This occurs when the motor is taking too much current with reference to the value in Group 99, motor data. POSSIBLE FIXES: 1. Check that motor’s load is not excessive. 2. Check acceleration time – too fast an acceleration of a high inertia load will cause too.
[pdf] Inverters can be classed according to their power output. The following information is not set in stone, but it gives you an idea of the classifications and general. .
Specifications provide the values of operating parameters for a given inverter. Common specifications are discussed below. Some or all of the specifications usually. .
Determine the power that a solar module array must provide to achieve maximum power from the SPR-3300x inverter specified in the datasheet in Figure 1. Solution Because POUT (efficiency)(PIN) PIN = POUT/efficiency Using peak efficiency, the input power to the inverter must be PIN=POUT/Peak Efficiency=3,300 W/0.953=3,463 W.
[pdf] An inverter converts a 110 Volt DC voltage (battery) into an AC voltage (230V-50Hz). The standard output voltage is 230 Volt, 50Hz with a pure sine wave. This means that this inverter supplies the same type of voltage as the wall socket. This allows any electrical device to work on it.
[pdf]